Autodesk®
TS16092983 - Vault Professional 2011 - Item Assign Hotfix
In a continuing effort to provide high quality products, Autodesk has released this hotfix which provides the following updates;
- Mapping item number from Blocks and Part References
- Lost detail ID during item assign
- BOM quantity gets multiplied when overriding tube and pipe length in Inventor
- Wrong BOM quantity when QTY has units and is set to "Static Quantity"
This README file highlights how to install this hotfix and other important information regarding this update.
Description of the Issues
System Requirements
Related Hotfixes and Utilities
Known Issues
Warnings
Files Affected
Update Verification
Installation Instructions
Description of the Issues
When assigning items for DWGs containing blocks and part references, file property mapping would not map properly to item numbers.
During assign item the detail ID could become lost for BOM entities.
When performing a quantity override on a decimal value in an Inventor BOM, the value entered resulted in a multiplication of the quantity.
Incorrect BOM quantity when the QTY is set to Static with units in Inventor.
Autodesk Data Management Server 2011 Update 2 (Professional)
Related Hotfixes and Utilities
- This hotfix replaces Vault hotfix TS16010228.
- Autodesk Inventor 2011 SP1 DL16094377 is required to resolve all issues.
It is strongly recommended to perform a back up prior to the application of this update.
This hotfix cannot be uninstalled. To revert to a pre hotfix state, a restore of a previous back up must be performed.
Connectivity.ProductStream.dll
The updated file is version 15.2.66.120.
Installation Instructions
- NOTE: Always ensure that a successful backup has been performed before applying any hotfixes.
- Open Autodesk Data Management Server Console and make sure all databases are fully migrated to the latest version.
- Migrate all unmigrated databases and libraries before proceeding.
- Close the Autodesk Data Management Server Console application.
- Run TS16092983.msp on the server to install the hotfix.
- Open a command prompt and navigate to the installed location of Connectivity.ADMSConsole.exe.
- Run Autodesk Data Management Server b2bmigrate operation in command line mode:
- Example: Connectivity.ADMSConsole.Exe -Ob2bmigrate -VUadministrator -VPadmin_password -DBUsql_user -DBPsql_password
- NOTE: Replace 'admin_password' with the appropriate administrator password for the -VP switch.
- The last two command line parameters are required only if the 'sa' password is not the default password.
- A 'migration successful' dialog will display when the b2bmigrate operation has completed.
- Reset the web service by typing 'iisreset' at the command prompt.
- Install the hotfix on all Autodesk Data Management servers.
Copyright © 2011 Autodesk, Inc.