- Crash occurs when switching the iAssembly members in some specific cases.
- The splices on the wires cannot be deleted if the wires are attached looms.
- The BOM cannot update if you change only the definitions of the wires or the ribbon cables.
- Cable wires can be routed into the different segment loop paths in specific cases.
- If a model has a flexible subassembly, motions do not display in Graphics.
- Modifying a DS parameter in the Parameters dialog box is slow.
- CER: Error alert dialog box displays when loading/unloading the Dynamic Simulation addin API command.
- "Duplicate Attribute name" message appears when importing motion loads after load-bearing face geometry is changed.
- Cannot update Stress Analysis if the "Export to FEA" part is suppressed and using "Export to FEA" again.
- Fails to get correct ISOGEN output for some special fittings.
- Flexible hose does not update after the related parts are moved by Drive Constraint.
- Wrong file extension for Bending Machine Output.
- Edit Fitting Orientation command is missing for fittings on elbow node which are replaced by other fittings.
- Crash occurs when you delete the fitting and switch the iAssembly members in some special cases.
- Fails to create new route when tube and pipe style applies the custom fittings published in local builds.
AUTODESK INVENTOR 2009
- EDM: Apprentice server cannot open everest dwg file.
- ApprenticeServer couldn't get instance after delete the Default.ipj.
- Inventor.Property.Value returns COMException 0x80004005 (E_FAIL) when the time zone of a machine is switched.
- Creating a GeneralNote without specifying a style is not using the active style.
- Creating a custom table using default table style results in incorrect formatting when using the DIN or GOST standard.
- SelectEvents causes Inventor to crash when you try to select an entity in a presentation document.
- VBA ThisDocument.InventorDocument does not work in some cases on 64bit machines.
- Inventor crashes when you close a migrated document.
- Calling GetMinimumDistance causes memory leak.
- Wrong value from curve evaluator on specific model.
- Documents.OpenWithOptions: causes a crash when the specified Project Library folder is not found.
- Inventor crashes on calling RunoffSurfaceDefinition.CreateRunoff.
- An Inventor crash occurs if you change Application Options->File->Default VBA project after running a VBA micro.
- Inventor crashes when you open files in ' ..\Samples\Models\Assemblies\Personal Computer\' folder.
- OnSolve::Context "DependentsChanged" value should be true after Drive Constraint.
- OnNewLevelOfDetailRepresentation events fired upon mirroring an assembly that has subassemblies with user defined LOD.
- NG: Inventor View crashes when you click the open button when the Default.ipj is missed in the Bin folder.
- Inventor crashes when you edit the dimension of a circle diameter with diameter autolimit linked.
- NG: File corruption occurs after a cosmetic weld is undone and the file is saved-closed-reopened.
- NG: Mass value does not update after material of the part is changed in the BOM.
- CER: Inventor crashes when you measure a solid that was promoted from the construction environment.
- CER: Crash occurs when editing direction of an assembly feature pattern in place.
- CER: Crash occurs when suppressing components after certain types of features are created.
- Some welded assemblies with assembly features cannot be opened.
- Inventor uses a lot of memory and does not release it when you measure distance several times with long delays in Assembly environment.
- Inventor is delayed when modifying a parameter coming from Dynamic Simulation and Stress Analysis.
- Mass properties display invalid density values for some part instances and the mass is calculated using this invalid density value.
- Mirror components that contains only numerals in its name causes a crash when the increment option is selected.
- Crash occurs when you suppress a component pattern in a subassembly with LOD active.
- Run time error after component pattern element suppression that contains a suppressed component with an assembly feature.
- Level of Detail Representations that call nested Level of Detail Representations do not work in some workflows.
- CER: Various Autodrop crashes.
- CER: Run time Error and crash occurs when you use Content Center after switching to another restricted windows user account.
- Fixed problems in Content Center Editor on Windows Vista when User Account Control (UAC) is active.
- Fixed the problem of rename a column of a linked family resets the family name in non-English Inventor versions.
- NG: Fixed a problem with the placing of parts published with corrupted thread information.
- Custom iProperties should show as evaluated value instead of expression.
- CER: Fixed a crash in the Family dialog box.
- Custom Colors are now applied on Content center components
- Fixed several of the problems in the Update tool.
- It is again possible to insert published part that contains tapered threads.
- Inventor can stop responding when switching to the Beam Graph page in Beam calculator.
- Incorrect values are set for materials if using Material Design scenario in Spur Gear generator with ANSI standard.
- The Worm Gear mechanism rotates in the opposite direction when moving the gear.
- NG: Some O-ring sizes cannot be inserted with the O-ring generator.
- CER: Some Design Accelerator dialog boxes randomly crash on initialization.
- CER: Random crash of Bearing Generator on startup.
- CER: Crash on using a sheet format with sheet scope revision table.
- CER: Heap error crash when opening large IDWs.
- CER: Random crash on editing title block.
- CER: Random crash on placing dimensions on a derived part view.
- CER: Random crash on saving an IDW that does not have its reference model.
- CER: Random crash on saving migrated R9 files.
- CER: Random crash when changing dimension arrowhead type.
- Deleting an iPart view from a drawing leaves an iPart reference that cannot be deleted.
- Holes created by using iFeatures have incorrect information in the drawing.
- Row Merge does not work for newly created legacy parts lists.
- Cannot create a section view using a view sketch.
- NG: User defined symbols (with user-defined insert point) are shifted after DWGOUT.
- NG: The dimension value for broken view is changed after DWGOUT.
- Jogged Radius displays incorrectly in AutoCAD when DWGOUT.
- AutoCAD (version prior to 2009) crashes if you open a DWGOUT file with certain text in sketched symbol.
- The sub-menu of markup status cannot be shown.
- Text is shrunk when publishing IDW to DWF/DWFX in invisible Inventor.
- CJK and Czech texts cannot be saved correctly to PDF.
- Text color cannot be saved correctly to PDF.
- PDF export is font dependent, which makes it very difficult to exchange a PDF document with non-CAD users.
- An arrow is not selectable inside a comment.
- Sheet number is empty when there are multi sheets.
- NG: Limitations of GOST title extension on sheet.
- Frame generator no longer accepts Construction line and Center lines.
- Capacity Meter - Physical Memory Mode is disabled on non-English operating systems.
- Cannot save BOM to an XLS on x64 platform with Excel 2007.
- Boundary patch cannot be created in R2009 on some loops of imported files.
- Boundary Patch could not select the edge in 2009 on some imported files.
- Preselect object from browser,and then invoke reverse face and change its type causes an Inventor crash in the Construction environment.
- Hole edge still remains B-Splines when migrating the files to version 2009 from version 11.
- Part with exported numeric parameter prompted to save when used in assembly.
- The lowest pitch size is selected by default for metric profile in the Hole dialog box.
- Subscription-Significant degradation in time required to select features to derive.
- Wrong values are shown in the Custom tab for the parameters exported as Number after Save.
- Inventor hangs by Edit feature of Inventor 10 file with imported sketch from DWG.
- CER: Crash due to delete feature.
- CER: Part crashes on rebuild.
- CER: Crash by inserting a derived part.
- CER: Create Emboss Feature on some special Face and check Wrap to face causes an Inventor crash.
- CER: Crash in Match shape a opened loop profile during Extrude.
- CER: Crash as creating Hole Notes.
- CER: Crash during Rebuild all.
- CER: Crash after Unsuppress extrusion.
- CER: Crash in Offset Naming.
- CER: Crash during Thread Preview linked.
- CER: Crash as editing sweep.
- CER: Crash in Face/Edge selections.
- CER: Crash due to bad edge selection.
- CER: Crash in Match shape a opened loop profile during Revolve.
- CER: Crash in face selections.
- CER: Crash as edit pattern.
- CER: Crash as creating pattern.
- CER: Crash in parameters dialog box when activating Custom Property Format.
- CER: Crash when you delete a part or turn off visibility, then highlight in part in tree.
- CER: Crash when using save as.
- CER: Crash when Migrate R2008 file to R2009.
- The Zoom select command causes the application to crash.
- When you open a customer migrated dataset, a crash occurs.
- You cannot edit the "included file" path in the Project Editor in Vista.
- NG: R2008 sheet metal styles migration causes poor computer performance even application error.
- NG: Flange bend position options change height extent when Old Method is checked and unchecked.
- CER: Crash during flange creation/editing due to invalid cut selection preview linked.
- CER: Crash when rolling back to the corner feature in a specific part.
- CER: When you switch between folded model and a legacy flat pattern model, a crash occurs if the legacy flat pattern is corrupted.
- CER: When you create flat pattern for a normal part generated by revolve feature, a crash occurs.
- CER: When you create flat pattern for a particular part with geometry replacement failure, a crash occurs.
- Deleting upstream features creating sickness creates a bad state where new SM features cannot be created.
- Crash when dragging the length of flange in graphic window for editing flange.
- Material iProperty for Sheet Metal is not set properly when part uses Sheet Metal material style rule.
- Sheet metal kFactor with multiple unitless units in the equation could not be evaluated.
- Flange is not adaptive when using New Method with bend position type except for Inside of bend face extents.
- Different selection order fails square and round corner relief for a symmetric gap.
- Center mark of rectangular patterned punch does not update following length change of sheet metal part.
- No geometry replacement for Jacobi corner when formed punch rep is selected.
- The flat pattern base face used causes geometry replacement failure.
- CER:Inventor crashes when placing 2D sketch on a surface removes a part.
- When you create a new style library located under the design data folder, multiple folder locations are created.
- When you harvest sheet metal styles, the SM styles that contain references to parameters are silently rejected by the Style Library Manager.
- The Style Library Manager reports differences when a legacy library is migrated, because of unit spacing.
- A dialog box displays after editing Options dialog box when opening a non-Inventor 3D format.
- Add an Environment Variable to forbid generating HTML translation report, to avoid Inventor hanging up on reading some 3D non-Inventor formats.
- Unable to save to IGES format from a part containing Deleted Face feature.
- Fail to import STEP files generated in MasterCAM.
- NG: Incorrect imported view on reading a STEP file.
- CER: Crash on saving some Inventor files as STEP format.
- When you select a drawing from vault to open in IPN create view, a crash occurs.
- When you open an assembly without local cc file from vault, resolve link dialog box displays.
- When you open a shared file from vault, nothing happens.
- When you select AutoCAD Drawing in File of type area in Open from Vault dialog box, the ACAD .dwg is not listed.
- When you create a saved search with specific folder and without subfolder, it returns different results in the Open from Vault dialog box.
- When you place a vaulted iPart member from vault into an assembly, Inventor recreates a new member instead of using the vaulted one.
- When you open an assembly from vault, with undo operation, a crash occurs.
- When you open an assembly which contains CC files multiple times, a crash occurs.
- When you place a custom LOD from vault, without local copies, the resolve link dialog box displays.
- When check in a drawing with DWF publish keep "Publish Screenshot" ON, the relationship between children and parents disconnects.
- CER: Inventor crashes when open or start a new part if the folder name for a project workspace contains the whole strings of library folder name.
- File always needs to be saved when you Open from Vault if the .ipt contains an image.
- The attachment cannot be downloaded from vault.
- Error dialog box displays when you check out the top assembly which is not in vault.
LEGAL NOTICE
Autodesk Inventor, Autodesk Vault, Autodesk Data Management Server, Autodesk Productstream, Autodesk Autoloader, AutoCAD,
AutoCAD Mechanical, Mechanical Desktop, and AutoCAD Electrical, are trademarks or registered trademarks of Autodesk, Inc. in
the United States and/or other countries.
Windows 2000, Windows 2003 server, Windows 2000 server, Windows XP, Windows Vista, Microsoft Office XP, Microsoft Office 2000, Microsoft Office 2003, Microsoft Office 2007, Microsoft Word, Microsoft PowerPoint, and Microsoft Excel are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries.
All other trademarks are the property of their respective owners.
We thank all our customers who identified these issues and reported them to us. These reports give us the opportunity to improve the product and provide you with the best solution in mechanical design. We also thank you for your continued business and for the feedback regarding the content of this update release.
Respectfully,
Autodesk Inventor Product Team