=================================================================
Notice to Autodesk Productstream Professional 2009 Customers
=================================================================

In a continuing effort to provide high quality products, 
Autodesk has released this hotfix which addresses cases 
described below.


=================================================================
CONTENTS
=================================================================

- Description of the issue
- System Requirements
- Known Issues
- Warnings
- Files Affected
- Update Verification
- Installation Instructions


=================================================================
Description of the issue:
=================================================================

This hotfix retrofits the following functionalities back into 
the Autodesk Mechanical Desktop 2009 add-in:

	- "Check State of Components" when opening an Autodesk 
		Mechanical Desktop assembly.
	- "New Engineering Document" on PS menu
	- "Transfer to Productstream" on PS menu
	- "Bill of Material" on PS menu
	- "Replace with newest version" on PS menu
	- "Edit external reference" on PS menu


=================================================================
System Requirements:
=================================================================

Productstream Professional 2009 SP1


=================================================================
Known Issues:
=================================================================

There are two issues for which workarounds exist.  Perform the 
following to address them: 
1. After installing the hotfix, launch Autodesk Mechanical 
	Desktop at least once before using it with Autodesk 
	Productstream Professional. 
2. Some icons and menu items may not display after installing 
	the hotfix.  To address this, perform the following:
	a. In Autodesk Mechanical Desktop, type 'CUI' (no quotes) 
		in the command line.
		i. You may obtain some error messages about missed cui 
			files.  Click 'OK' for all of them.
	b. In the CUI dialog, locate and expand the 'Partial CUI 
		Files' section.
	c. Right click on any 'PRODUCTSTREAM' entry and select 
		'Unload CUI File'
	c. Restart Autodesk Mechanical Desktop from Autodesk 
		Productstream Professional.


=================================================================
Warnings:
=================================================================


=================================================================
Files Affected:
=================================================================

x32-bit:
	[ClientDir]\cai\arx\aimdamcomp172.arx
x64-bit:
	[ClientDir]\cai\arx\aimdamcomp172.arx
	[ClientDir]\cai\arx\x64\aimdamcomp172.arx
Server:
	[ServerDir]\cai\Autodesk\Mdt\mdt2007.de\compass.cui
	[ServerDir]\cai\Autodesk\Mdt\mdt2007.fr\compass.cui
	[ServerDir]\cai\Autodesk\Mdt\mdt2007.it\compass.cui
	[ServerDir]\cai\Autodesk\Mdt \mdt2007.uk\compass.cui
	Profile_ADSK_TS1103387.txt


=================================================================
Update Verification:
=================================================================

Client files' version is 8.1.41.0
Server files' 'Date Created' is 2009/02/12


=================================================================
Installation Instructions:
=================================================================

1. Unzip the package 
2. Copy and Paste the following files into the appropriate 
folders:
	a. Client:
		i. For x32-bit:
			[ClientDir]\cai\arx\aimdamcomp172.arx
		ii. For x64-bit:
			[ClientDir]\cai\arx\aimdamcomp172.arx
			[ClientDir]\cai\arx\x64\aimdamcomp172.arx
	c. Server:
		[ServerDir]\cai\Autodesk\Mdt\mdt2007.de\compass.cui
		[ServerDir]\cai\Autodesk\Mdt\mdt2007.fr\compass.cui
		[ServerDir]\cai\Autodesk\Mdt\mdt2007.it\compass.cui
		[ServerDir]\cai\Autodesk\Mdt \mdt2007.uk\compass.cui
3. On Vista operating systems, disable the User Account Control 
	(UAC) option and reboot the operating systems.
4. Launch Autodesk Mechanical Desktop before using it with 
	Autodesk Productstream Professional.
5. Import 'Profile_ADSK_TS1103387.txt'
	a. Login as Administrator in Productstream Professional.
	b. Open the configuration editor by navigating to Tools -> 
		Profile Manager...
	c. Select a profile over CUSTOMER:SYSTEM: the import button 
		will be available: click it and browse to select the 
		'Profile_ADSK_TS1103387.txt' file
	d. Click on "exit" to close PSP. The client has to be 
		restarted to read the new configuration
6. On Vista operating systems, you may choose to re-enable the 
	User Account Control (UAC) option, but only after opening a 
	dwg at least once in Autodesk Mechanical Desktop from 
	Productstream Professional. 

=================================================================

Thank you for your commitment to Autodesk products.

Respectfully,
Autodesk Data Management Team
