Notice to Autodesk Productstream Professional 2009 Customers
=================================================================

In a continuing effort to provide high quality products, 
Autodesk has released this hotfix which addresses cases described 
below.


====================================================
CONTENTS
====================================================

- Description of the issue
- System Requirements
- Known Issues
- Warnings
- Files Affected
- Update Verification
- Installation Instructions

This hotfix contains an unusally large number of changed dlls. Although validated and
tested by Autodesk, you are encouraged to verify in a test environment. Please note 
that there is no automated uninstall for this package.

====================================================
Description of the issue:
====================================================

This hotfix addresses the following issues.

- Several important Stability improvements
  These fixes are based on the review of a number of frequent crashes reported 
  to Autodesk via the CER mechanism

- Replication of deleted elements
  If there are deleted elements in the the PSP wastebasket, Replicator replicates
  the deleted elements. This can have performance impacts when there are very many
  deleted elements and their IDENTS are re-used. This hotfix also requires a server
  side change, available as TS1101447.
  
- The Errlog.err file grows continuously after closing the PSP client
  This fixes the re occurence of a problem originally reported in the previosu release

- Dwg files get corrupted after using the "dxfout" command in AcadM
  

- Filtering inside SML with combo box 
  Defining a combo box selection with different values for database and GUI cannot 
  be filtered in CRCList.


====================================================
System Requirements:
====================================================

Productstream Professional 2009 + SP1

Hotfix - TS1101447 (this server side hotfix is required the fix for the replication
of deleted elements. It is only applicable is Replicator is being used)

====================================================
Known Issues:
====================================================

====================================================
Warnings:
====================================================

====================================================
Files Affected:
====================================================

aimcontainer.dll
aimcrclist.dll 
aimdatasheet.dll 
aimfolderbar.dll
aimieview.dll     
aimlist.dll different 
aimpreview.dll     
aimpreviewcontainer.dll
aimpreviewdwfview.dll  
aimpreviewieview.dll   
aimsection.dll       
aimsplitter.dll      
aimtab.dll           
aimtree.dll          
aimtreelist.dll      
cai_call.dll         
compass.exe         
compass_server.dll  
designer.dll        
aimdambom172.arx  

====================================================
Update Verification:
====================================================

FileVersion for all the dlls: 8.1.40.0

====================================================
Installation Instructions:
====================================================

for x86:

> <double click> Patch_for_PSP2009_SP1_x86.msp

for x64:

> <double click> Patch_for_PSP2009_SP1_x64.msp


================================================================================

Thank you for your commitment to Autodesk products.

Respectfully,