Autodesk®
TS16010228 - Vault Professional 2011 - Item Assign Hotfix

In a continuing effort to provide high quality products, Autodesk has released this hotfix which provides the following updates;

  1. Mapping item number from Blocks and Part References
  2. Lost detail ID during item assign

This README file highlights how to install this hotfix and other important information regarding this update.

CONTENTS

Description of the Issues
System Requirements
Related Hotfixes and Utilities
Known Issues
Warnings
Files Affected
Update Verification
Installation Instructions

Description of the Issues

When assigning items for DWGs containing blocks and part references, file property mapping would not map properly to item numbers.

During assign item the detail ID could become lost for BOM entities.

System Requirements


  • Autodesk Data Management Server 2011 Update 2 (Professional)

  • Related Hotfixes and Utilities



    Known Issues



    Warnings


    It is strongly recommended to perform a back up prior to the application of this update.

    This hotfix cannot be uninstalled. To revert to a pre hotfix state, a restore of a previous back up must be performed.


    Files Affected


  • Connectivity.ProductStream.dll

  • Update Verification

  • The updated file is version 15.2.66.110.
  • Installation Instructions


    1. NOTE: Always ensure that a successful backup has been performed before applying any hotfixes.
    2. Open Autodesk Data Management Server Console and make sure all databases are fully migrated to the latest version.
    3. Migrate all unmigrated databases and libraries before proceeding.
    4. Close the Autodesk Data Management Server Console application.
    5. Run TS16010228.msp on the server to install the hotfix.
    6. Open a command prompt and navigate to the installed location of Connectivity.ADMSConsole.exe.
    7. Run Autodesk Data Management Server b2bmigrate operation in command line mode:
      1. Example: Connectivity.ADMSConsole.Exe -Ob2bmigrate -VUadministrator -VPadmin_password -DBUsql_user -DBPsql_password
      2. NOTE: Replace 'admin_password' with the appropriate administrator password for the -VP switch.
      3. The last two command line parameters are required only if the 'sa' password is not the default password.
    8. A 'migration successful' dialog will display when the b2bmigrate operation has completed.
    9. Reset the web service by typing 'iisreset' at the command prompt.
    10. Install the hotfix on all Autodesk Data Management servers.


    Copyright © 2011 Autodesk, Inc.